IMPORTANT PRECAUTIONS

Before handling the FB3000 boards or other system components, a service
technician must always use PSD Precautions.

•

Electrostatic Discharge (ESD) can easily damage the
FB3000 board assemblies.

•

Remove the anti-static packing only when the parts are
ready for installation.

•

Handle the boards by their edges, and avoid touching their
components.

TROUBLESHOOTING

Error Condition(s)

Solution(s)

• Check that scale is empty.
• If Scale is empty, Call for

Service.

• Load Cell(s) bad.

• A large amount of weight is zeroed.
• This

is

normal.

• Press

OK

and continue weighing.

• Possible load cell damage.
• Call for Service.

• Load Cell Failure(s)
• Flashing and displays “

- - - -

“

• Possible load cell damage.
• Call for Service.
• Access

the

Load Cell Diagnostics Menu

to verify the

load cell status.

• Count stability or change of counts.
• Contact the local service for further trouble-shooting.

SC Cells Found None

• Possible damaged load cell cable.
• Load

cell

shortened.

• Defective Pit Power Supply.
• Defective Smart Sectional Controller(s).
• Defective Analog Assembly.
• Call for Service.

Displays “

- - - -

“ ~ lb GROSS

• Communication error to load Cells.
• Call for Service.

NOTE:

Call the

Fairbanks Service Department

for all unit updates, repairs,

and further advice on the FB3000 In/Out Program.