Section 5: Operations

6/08

76

51195 Rev. 1

Defining Fields in the Formatting Window, Continued

Field

DESCRIPTION

Fixed or

Random Wt.

Displays whether the item is preprogrammed with a specific

Fixed

weight

amount, or if the weight amount is

Random

.

• When item(s) are to be sold as a specific weight, select

Fixed Wt

.

Example:

Packaged product may be sold in 1 lb. containers. The label

displays a net weight of 1 lb for every package produced.

The fixed weight

displayed equals the product’s Minimum Weight Value.

If the caption reads

“Fixed”,

then the Product Minimum Weight is printed

on the Label, not the actual weight.

• When the weight of an item varies from package to package, select

Random

Wt

.

Example:

Product in a food processing plant is often “sold by the pound”

and varies in weight per case. When printing random weights, the actual
Net Weight Value displays on the label.

If its

Random

, the actual product net weight is printed on the label.

Packed On

Displays the date when an item was packed.

Pallet #

Identifies the serial number of the pallet currently being processed.

Used for tracking purposes.

Count

Displays how many units are completely processed out of the pallet total.

Factory #

Identifies the specific vendor factory code number.

Station #

Identifies which specific station is processing the item.

Lot #

A programmed number that identifies which Lot is currently processing.