Eliminate mechanical constraints – The vessel should be fully supported on
the Omnicells. Reduce or eliminate any mechanical issues which will interfere with
the vessel’s deflection, such as: rigid vertical or horizontal piping (use flexible
piping when connecting to the vessel whenever possible), ladders, catwalks, etc.

Orientation – Orientation of the 9104 FB Series Omnicell should match the
double-ended shear beam load cell design, however it is recommended
positioning the load cell cables away from traffic areas. Reference the orientation
drawings.

Heated or chilled vessels

Consult with the appropriate Product Manager for

any application with vessels that heat or chill the product inside the vessel.

In these cases, special consideration may be required to isolate the temperatures.

Load cell cabling – The load cell cables should be routed away from areas
where they could be damaged. Use drip loops at both the load cell and the
junction box ends.

Hazardous area – If the Omnicells will be installed in a Hazardous Area, a
document is required from the end user stating the Class, Division, and Group.