Section 4: Electrical Installation

07/13

18

51325 Rev. 1


Notes:

This Omnicell is designed to provide protection from the effects of
moisture. The load cells is calibrated with the cable attached, and
therefore the cable should NOT be cut.

The cable is connected directly to the junction box or SSC through a sealed
bushing that MUST be tightened properly to keep water/moisture out of the box.

All cabling must have a drip loop at the cell or box entry location to help
prevent water entry.

On all boxes, particularly stainless steel, the black plastic fittings have “O”
rings that can be forced out of position if the bushing itself is not tight.

To prevent this, first tighten the inner nut securing the bushing in the hole,
then insert cable and carefully tighten the gland until it is very snug.

Do not over-tighten where bushing turns.

Secure the cover.