21

51325 Rev. 1

Section 5: Maintenance

5.1. SCALE MAINTENANCE

1.

Check for accumulations of solid material under the Omnicells that may affect the
accuracy (ice, frozen mud, debris).

2.

Check to see that the customer is doing routine cleaning around the vessel.

3.

Inspect load cells for damage to the ends/cables.

4.

Inspect and adjust all check bolts (if applicable) using anti-seize on the threads.

5.

Check for all clearances around the scale for any obstructions or interference with
the free movement of the platform.

6.

Check all load cells for plumb and level.

7.

Inspect the boxes for leaks; the interior should be clean and dry. If there is
moisture inside, clean and dry it thoroughly. Check all connections at the
terminal blocks to ensure they are tight.