Appendix I: Specifications

Capacities

1K to 75K lbs

Mount construction

Nickel-plated mild alloy steel; stainless steel

Load cell:

Full scale output (FS)

3.0 mV/V/ohm ± 0.1%

Combined error

≤ 0.05% FS

Non-linearity

≤ 0.03% FS

Creep error (20 min.)

≤ 0.03% FS

Compensated
temperature

14° F to 104° F (-10° C to 40° C)

Excitation voltage

5-15 VDC

Overload

Safe = 150%; Ultimate = 300%

Sideload

100% FS

Uplift

100% FS

Bridge resistance

700 ohms nominal

Construction

Alloy steel; Stainless steel 17-4 PH

Cable

Polyurethane: 20ft.

Approvals

NTEP #13-039, Alloy steel load cells 20K-75K capacities