Finish Thompson GP11 SERIES User Manual

Assembly, Installation

Advertising
background image

ASSEMBLY

Unpack pump from carton and check for shipping damage.

PUmPs With motor

No assembly required. simply unpack the pump and motor and

examine for any shipping damage. if damage is detected, save

the packaging and notify the carrier immediately.
remove the shipping plugs from the suction and discharge of

the pump and proceed to the “installation requirements” sec-

tion of these instructions.

PUmPs WithoUt motors

1. Unpack the pump and examine for any shipping damage.

if damage is detected, save the packaging and notify the

carrier immediately. Use the “supplied and optional Parts”

section of these instructions to verify that all items have

been received.

2. Prepare to install the pump onto the motor.

a. remove the protective shroud (item 22) from the motor

adapter (item 6).

b. Ensure that the set screws in shaft adapter (item 20)

are loosened to avoid interference when installing.

c. Coat the motor shaft with an anti-seize compound prior

to installation.

3. Properly adjust the spacing between the impeller (item 3)

and the housing cover (item 2).

NotE: Proper spacing of the impeller to the housing cover

is critical for performance and to avoid damage to pump

components. A .050” gap is required.

a. slide the shaft adapter onto the motor shaft until the

impeller is tight against the inside of the housing

cover (look through the pump’s discharge to verify).

make sure that the shaft adapter’s set screws do not

line up into the motor shaft’s key way.

b. temporarily bolt the motor adapter to the motor, placing

shims (flat washer - item 10) between the motor

adapter and the motor using two hex-head cap screws

(item #11) 180° apart (see Figure 1).

c. tighten the four set screws from the shaft adapter onto

the motor shaft.

d. remove the two temporary hex-head cap screws and

shim washers.

4. Pull the motor adapter flush against the motor face. install

GP11 SERIES Sealed

Non-Metallic Centrifugal Pumps

Installation and

Maintenance Instructions

four hex-head cap screws and flat washers through the

motor adapter and into the motor and tighten.

5. Verify there is a .050” gap between the impeller and hous-

ing cover by looking into the discharge of the pump.

6. reinstall the protective shroud.
7. install the pump into your system according to the “instal-

lation requirements” section of these instructions.

INSTALLATION

moUNtiNg

motor or base plate must be securely fastened.

PiPiNg

Always support the piping near the pump to minimize

stress and strain on the pump’s casing.

minimize frictional losses by increasing the piping size by

one diameter.

Use a minimal number of bends, keeping any bends at

least a distance of ten pipe diameters away from the pump.

install valves on the suction and discharge lines. Place the

valves within a distance of ten pipe diameters away from

the pump.

Ensure that the piping is leak free.

Position the pump as close to the liquid source as possible.

maintain a flooded suction at all times.

PUmPs With CooliNg (PrEssUrE) CollArs

A cooling collar provides a water flush to the pump’s seal. this

is necessary when pumping hot liquids or liquids that tend to

build up or crystallize around the seal faces. if your pump is

supplied with a cooling collar, proper water flow and pressure

are critical to the operation of the pump.
1. Plumb a water supply to the cooling collar. Use 1/8” NPt

threaded holes for the water inlet and drain lines. Either

hard pipe or flexible tubing is suitable.

2. Adjust the water flow and pressure of the flush/cooling

water BEForE starting the pump.

Figure 1

1

Advertising