Finish Thompson AC 4 & 5 HORIZONTAL SERIES User Manual

Finish Thompson Pumps

Advertising
background image

1

discharge, a vacuum switch on the suction, or a motor minder to

monitor motor current draw.

PUMPING LIQUIDS THAT MAY SOLIDIFY OR CRYSTALLIZE:
Add a flush system to the pump’s piping to prevent accumulation of material

inside the pump. Install water inlet and outlet valves as shown in Figure 1.
Refer to the “Operation” section of these instructions for the flush procedure.

ELECTRICAL CONNECTIONS

1. Perform the motor wiring according to NEC requirements and local

electrical codes.

2. Wire the motor for clockwise rotation when facing the fan end of the

motor.

3. To verify correct rotation of the motor:
a. Install the pump into the system.
b. Fully open the suction and discharge valves.

c. Allow fluid to flow into the pump. Do not allow the pump

to run dry. Running the pump dry can damage internal parts.

d. Jog the motor (allow it to run for only 1-2 seconds) and

observe the rotation of the motor fan. Refer to the directional

on the arrow pump if needed.

NOTE: A pump running backwards will pump, but at a greatly

reduced rate.

OPERATION

FLOODED SUCTION SYSTEMS
1. Fully open the suction and discharge valves.
2. Start the pump and verify liquid is flowing. If there is no liquid

flow, refer to the “Troubleshooting” section of these instructions.

3. Adjust the flow rate and pressure by regulating the discharge valve.

CAUTION: Never attempt to adjust the liquid flow with the suction

valve. Limiting suction will damage pump components.

FLUSHING SYSTEMS EQUIPPED WITH FLUSH VALVES:
1. Fully close the suction and discharge valves.
2. Connect the water supply to the water inlet valve and connect a

drain hose to water outlet valve.

3. Turn on the water supply and open the inlet and outlet valves. Flush

the system until the pump has been cleared of any material buildup

(usually approximately 5 minutes).

4. Close the water inlet and outlet valves and turn off water supply.

ASSEMBLY

PUMPS WITH MOTORS
1. No assembly required. Unpack the pump and motor and examine

for any signs of shipping damage. If damage is detected, save the

packaging and notify the carrier immediately.

2. Proceed to the “Installation” section of these instructions.
PUMPS WITHOUT MOTORS
Note: Do not remove shipping plug located in suction port of the

pump until the pump is completely assembled onto the motor.
1. Unpack the pump and examine for any signs of shipping damage.

If damage is detected, save packaging and notify the carrier immediately.

2. Place the motor on the fan cover. Align any set screw (item 9) with

key slot in motor shaft. Place the aluminum motor adapter (item

8) onto the motor rabbet. Position the slot (shaft sleeve set screw

access hole) in motor adapter with the top of the motor. Line up

the bolt holes in the motor adapter with the bolt holes in the motor

face. Install (4) bolts and lock washers (items 10,11). Securely

tighten.

3. Through the top and bottom access holes, tighten securely two of

the four set screws on the shaft adapter (item 6). You will need an

1/8” Allen wrench for this.

4. Remove the screw from the shipping plug and then remove the plug

from the suction port. Rotate the motor fan until you can tighten

the two remaining set screws on the shaft adapter.

5. Rotate the motor fan by hand and check for impeller rubbing. If

the impeller rubs loosen the shaft adapter set screws and adjust

the impeller accordingly. Retighten the shaft adapter set screws.

6. Proceed to the “Installation” section of these instructions.

INSTALLATION

MOUNTING

Motor or base plate must be securely fastened.

PIPING TO AND FROM THE PUMP

• Always support the piping near the pump to minimize stress

and strain on the pump’s casing.
• Minimize frictional losses by increasing the suction piping size

by one diameter.
• Use a minimal number of bends on suction piping. Keep

bends beyond a distance of ten pipe diameters from the pump.
• Install shut off valve on the suction line and flow control valve

in the discharge line. Place the valves beyond a distance of ten

pipe diameters from the pump.
• Ensure that the piping is leak free.
• Position the pump as close to the liquid source as possible.
• Maintain a flooded suction at all times or prime the pump and

maintain prime at all times.

CAUTION: Suction prime must be maintained at all times.

Running the pump dry will cause damage to pump components.

To protect the pump if prime is lost, use a pressure switch on the

AC 4 & 5 HORIZONTAL SERIES

Sealed Metallic Centrifugal Pumps

Installation and Maintenance Instructions

Figure 1