1

1

Caution: Pump assembly may be top heavy.

6. Rotate the pump and the mounting plate if ordered to the desired ori-

entation. Align the holes in the mounting plate and the motor adapter

with the holes in the motor face. Secure the mounting plate and motor

adapter to the motor using the correct bolts and washers (items 6,7,

and 8) from the hardware package.

7. Check and verify the locking rings are securely snapped in place and

did not loosen during shipping. Rotate the motor fan to check for binding

or rubbing inside the pump.

8. Install the pump into the system according to the installation instruc-

tions provided.


5. Install the coupling insert (yellow internally splined plastic sleeve) onto

the coupling half on the motor shaft. Carefully slide the motor adapter

(item 9 in figure 6) onto the motor making sure the pump shaft coupling

matches up with the plastic insert and seats properly. Make sure rabbet

on the motor is firmly seated into the motor adapter.

Caution: Improper positioning of the metric motor adapter can

cause premature coupling failure or cause the pump shaft to bottom

out before the pump is properly installed onto the motor adapter.

6. Rotate the pump discharge and the mounting plate if ordered to the

desired orientation. Align the bolt holes on the mounting plate with

the motor adapter (item 9 in figure 6) and the metric motor adapter

flange (item 2 in figure 6). Secure with the hardware provided.

Caution: Pump assembly may be top heavy.

7. Check and verify the locking rings are securely snapped into place and

did not loosen during the assembly process. Rotate the motor fan to

check for binding or rubbing inside the pump.

WaRninG: Magnetic field hazard. This pump contains powerful rare

earth magnets. When the pump is disassembled (not connected to a

motor) and the magnets are exposed, these magnets produce power-

ful magnetic fields. Individuals with cardiac pacemakers, implanted

defibrillators, other electronic medical devices, metallic prosthetic

heart valves, internal wound clips (from surgery), metallic prosthetic

devices or sickle cell anemia must not handle or be in the proximity of

the magnets contained inside the pump. Consult a health care provider

for specific recommendations before working with this pump.

PumPs with motors
1. No assembly required. Simply unpack the pump and motor and examine

for any signs of shipping damage. If damage is detected, save the

packaging and notify the carrier immediately.

2. Ensure that lock rings are securely snapped in place and did not loosen

during shipment.

3. To install the pump into the system, follow the installation instructions

provided.

msVKC series

sealless Non-metallic Vertical Pumps

installation and maintenance instructions

assembly

PumPs without motors

1. Unpack the pump and any supplied accessories. Examine for shipping

damage. If damage is detected, save the packaging and notify the

carrier immediately.

2. Prepare to assemble the pump onto the motor by placing the motor

on the fan cover on a suitable clean, level work surface.

3. Install motor key into motor shaft key slot. Align the keyway slot on

the flywheel (item 35 in figure 5) and slide the flywheel onto the mo-

tor shaft with the protruding boss towards the motor face. Align the

keyway slot in the top coupling half (item 29 in figure 5) and slide the

coupling half on. Set coupling half with the motor shaft recessed 7/32”

and tighten both setscrews with a 1/8” Allen wrench to 70 in-lbs.

4. Slide the flywheel forward so that it rests against the backside of the

coupling half. Tighten both setscrews.

5. Install the coupling insert (yellow internally splined plastic ring) onto

the coupling half on the motor shaft. Place coupling support (item

38A in figure 5) into center of coupling half with the short side facing

the motor. Carefully slide the motor adapter end (item 9 in figure 5)

of the pump assembly over the motor shaft until both coupling halves

are completely seated in the coupling insert. Make sure rabbet on the

motor is firmly seated into the motor adapter.

2. Prepare to assemble the pump onto the motor by placing the motor

on the fan cover on a suitable clean, level work surface.

3. Install the keyway into the motor shaft key slot. Align the keyway slot

in the coupling half (item 29, figure 6), and slide the coupling half onto

the motor shaft with the splined side facing the pump. Set the coupling

half with the motor shaft recessed 11.1 mm. Tighten both setscrews

with a 1/8” Allen wrench to 7.9 N-m.

4. Install the metric motor adapter (item 2 in figure 6) onto the motor. To

aid in correct installation, the letters “A” & “B” are molded onto the

opposite sides of the motor adapter. For 71 frame motors, using the

correct hardware (items 3,4 and 5 in figure 6) mount the adapter with

side “B” facing up. For 63 frame motors, using the correct hardware

(items 3,4 and 5 in figure 6) mount the adapter with side “A” facing

up. See figures A & B.

Pat. No. 5,708,313

1. Unpack the pump and any supplied accessories and examine for

damage. If any damage is detected, save the packaging and notify

the carrier immediately.

note: Finish Thompson has added extra weight (Flywheel item 35 in Figure

5) to several of our MSVKC Series Pumps to slow down motor start

up & prevent possible magnet decoupling. It is necessary to know

whether your pump was supplied with the flywheel. Flywheels are

supplied with all 56C NEMA & 80 Metric frame motor adapters. If you

are unsure whether your pump was supplied with a flywheel, please

contact FTI’s Tech Service Department at PH: 800-888-3743 or email

[email protected].

note: Motor assembly videos are available online at www.finishthomp-
son.com/downloads/maintenance videos.

For 56C Frame adaPters with Flywheel (item 35 iN Figure 5):

For 63, 71 metriC Frame adaPters without Flywheel (use
Figure 6):

Figure A