Finish Thompson STATIC PROTECTION KIT User Manual

Assembly instructions, Static protection kit, Part no. applicable model

Advertising
background image

Part No.

Applicable Model

A100835, A100838

TTS, STTS, TBS, PFS

A100836

BTS, HVDP

A101521, A101521-1 TTS, STTS, TBS, PFS

A100961

TMS Mixer

107429

EFS

GROUND WIRE ASSEMBLY ATTACHMENT

TO MOTORS

Motor Type: Electric Explosion Proof

Unscrew the #10-32 plated nut that is installed on the exposed
screw extending from the motor housings (Do not remove the
standard hex nut from this screw). Attach #10 ring terminal from
the end of the ground wire assembly to exposed machine screw
using the wing nut and #10 lock washer. The lock washer is
included in the static protectin kit. Contact Finish Thompson Inc.
if a replacement #10-32 wing nut is needed.

Motor Type: Air

Remove one of the Allen head set screws from the motor mount.
Slide 1/4-20 x 1/4” round head machine screw through 1/4” ring
terminal on ground wire assembly (the 1/4” ring terminal is the
2

nd

terminal from the end of the wire assembly). Thread 1/4-20

plated nut onto screw. Insert screw into hole on motor mount and
tighten (do not over tighten). Using a 7/16” wrench, tighten 1/4-
20 nut against the ring terminal.

ASSEMBLY INSTRUCTIONS

STATIC PROTECTION KIT

WARNING: PUMPING OR MIXING FLAMMABLE LIQUIDS CAN CREATE STATIC ELECTRICITY,
WHICH CAN CAUSE EXPLOSION AND FIRE RESULTING IN INJURY OR DEATH. ALL CONTAINERS
MUST BE METAL AND GROUNDED.

ASSEMBLY FOR PUMPS

Step I

- Place stainless steel hose clamp on end of hose and

slide hose over pump discharge spout. Tighten hose clamp.

Step 2

- Attach ground wire assembly to motor using the appro-

priate instructions found on the left half of this page.

Step 3

- Unscrew and remove the #8-32 x 1/4” brass screw and

#8 brash lock washer from the pump and attach the remaining #8
ring terminal from the ground wire assembly (3

rd

terminal from

the end of the ground wire assembly) using the brass screw and
lock washer. Contact Finish Thompson Inc. if replacement screw
and washer are needed.

Step 4

- Attach ground wire assembly to the hose using the #8

ring terminal (4th terminal from the end of the wire assembly)
and the supplied #8-32 x 1/4” brass screw and #8 brass lock
washer.

Step 5

- Check electrical continuity between all components of

the ground wire assembly. Ensure there is electrical continuity
between the ground clamp and and the motor connection, the
ground clamp and the hose connection, and the ground clamp
and the pump connection. The resistance must be one (1) ohm
or less. If it is greater than one ohm, recheck all connections.

ASSEMBLY FOR MIXERS

Step 1

- Attach ground wire assembly to motor using the appro-

priate instructions found on the left half of this page.

Step 2

- Unscrew and remove the #8-32 x 1/4” brass screw and

#8 brash lock washer from the mixer tube and attach the #8 ring
terminal from the ground wire assembly using the screw and
lock washer. Contact Finish Thompson Inc. if replacement screw
and washer are needed.

Step 3

- Check electrical continuity between all components of

the ground wire assembly. Ensure there is electrical continuity
between the ground clamp and and the motor connection and the
ground clamp and the mixer connection. The resistance must be
one (1) ohm or less.

Advertising