Finish Thompson KC 5.5, 6, 6H, 7, 8, & 10 SERIES User Manual

Finish Thompson Pumps

Advertising
background image

1

PUMPS WITHOUT MOTORS

63/B14, 71/B14 & 80/B14

1. Remove pump, drive magnet assembly and hardware

package from box.

CAUTION: Keep away from metallic particles, tools

and electronics.

2. Remove screws and washers (items 9A, 9B & 9C) from

impeller housing (item 1) and remove pump assembly

from motor adapter (item 5).

3. For 63 frame pumps - Adjust the single setscrew located in

the middle of the supplied shaft adapter so that it protrudes

slightly into the inside bore. Align that protruding setscrew

with the keyway or flat on the motor shaft and slide on the

shaft adapter until it bottoms out. Tighten the single set-

screw into the keyway, and then tighten the two setscrews

on the end of the adapter onto the motor shaft.

4. Install the motor adapter (item 5) onto the motor with the

access holes top and bottom. Secure with supplied hard-

ware (items 10A, 10B, and 10C). On 63 frame pumps,

from the motor side, insert the supplied gray spacer into the

base of the motor adapter and secure both to the motor.

5. For 63 frame pumps - Screw the cone point drive magnet

assembly setscrew (item 6B) in so that it protrudes

slightly into the drive bore. Align the protruding setscrew point

KC 5.5, 6, 6H, 7, 8, & 10 SERIES

Non-Metallic Centrifugal Pumps

Installation and Maintenance Instructions

10A,10B, & 10C) from hardware package.

4. Manually rotate pump assembly to ensure that the pump

is not binding or rubbing on the drive magnet assembly.

5. Install the pump into the system according to installation
instructions.

ASSEMBLY

Unpack the pump, drive magnet assembly and hardware package

from carton and check for shipping damage.

WARNING: Magnetic field hazard. This pump contains powerful

rare earth magnets. When the pump is disassembled (not connected

to a motor) and the magnets are exposed, these magnets produce

powerful magnetic fields. Individuals with cardiac pacemakers,

implanted defibrillators, other electronic medical devices or sickle

cell anemia must not handle or be in the proximity of the magnets

contained inside the pump. Consult a health care provider for specific

recommendations before working with this pump.

ATEX COMPLIANT PUMPS

All assembly, installation, and maintenance instructions are the same

as standard pumps with the exceptions noted on page 4 under “Safety

Precautions for ATEX pumps.”

PUMPS WITH MOTORS

Proceed to Installation Section.

PUMPS WITHOUT MOTORS

56C frame

1. Remove the pump, drive magnet assembly and hardware

package from box.

CAUTION: Keep away from metallic particles, tools and

electronics. Drive magnets MUST be free of metal chips

.

2. Slide drive magnet assembly (item 6) onto the motor shaft

until it is between 3.110” and 3.120” as measured from the

motor face to the top of the drive magnet assembly. See

Figure 1. Align set screw (item 6B) with flat or key slot on

the motor shaft and tighten both setscrews with a 5/32” Al-

len wrench to 70 in.-lbs. (7.9 N-m ).

CAUTION: Do not operate/test the motor with the drive mag

net assembly exposed.

WARNING

: Magnets are strong. To avoid damage and pinch-

ing fingers, tightly grasp pump assembly keeping finger tips

away from the area where the motor adapter and motor meet.

3. Carefully slide the pump assembly over the drive magnet

assembly. Orient the discharge port to either the 12 or

9 o’clock position. Make sure rabbet (step) on motor is fully

seated into the motor adapter (item 5). Align bolt holes in

motor adapter and motor. Install (4) bolts and washers (items

Figure 1