• Minimize frictional losses by increasing the suction piping size

by one diameter.
• Use a minimal number of bends on suction piping, keeping

any bends a minimum of ten pipe diameters from the pump.
• Install a shut off valve on the suction line and a flow control

valve in the discharge line. Place the valves a minimum of ten

• pipe diameters from the pump.
• Ensure that the piping is leak free.
• Position the pump as close to the liquid source as possible.
• Maintain a flooded suction at all times or prime the pump and

maintain prime at all times.

CAUTION: Do not run the pump dry. This pump should

never be started without liquid in the casing.
The fluid being transferred by the pump lubricates the pump

components. Even short periods of running the pump dry

could damage the pump. It is recommended that run dry

protection be used.
Optional electronic power monitors are available to help pro-

tect against run dry.

PUMPIng lIqUIDs ThaT May sOlIDIfy Or crysTallIzE

add a flush system to the pump’s piping to prevent accumulation

of material inside the pump. Install water inlet and outlet valves

as shown in figure 1. refer to the “Operation” section of these

instructions for the flush procedure.

Figure 1

ElEcTrIcal cOnnEcTIOns

1. Perform the motor wiring according to nEc requirements and

local electrical codes.

2. Wire the motor for clockwise rotation when facing the fan end

of the motor.

3. To verify correct motor rotation
a. Install the pump into your system.
b. fully open the suction and the discharge valves.
c. allow fluid to flow into the pump. Do not allow the pump to

run dry, as this will cause damage to the seal components.

assEMBly

PUMPs WITh MOTOrs

1. no assembly required. Unpack the pump and motor and exam-

ine for any signs of shipping damage. If damage is detected,

save the packaging and notify the carrier immediately.

2. Proceed to the “Installation” section of these instructions.

PUMPs WIThOUT MOTOrs

Note:

Do not remove shipping plug located in suction port of

the pump until the pump is completely assembled onto the

motor.
1. Unpack the pump and examine for any signs of shipping dam-

age. If damage is detected, save the packaging and notify the

carrier immediately.

Special Note: AC6HJS 90 frame only -

a. Using the hardware provided (items 9, 10, & 11), bolt

the motor adapter (item 8) to the motor.

b. attach the mounting plate (item 14) to the motor

adapter using the hardware provided (items 12 & 13).

c. Proceed to page 2 of the Installation and Maintenance

Manual and follow steps 1 through 9 under “reassembly.”

2. Insert key into motor keyway. Visually determine key location

in pump end. align keyway slots on motor shaft and pump

impeller sleeve. slide pump assembly over the motor shaft

until the pump motor adapter (item 8) is completely seated

over the motor rabbet. The drain slot should always be on

the bottom. Install 4 bolts with flat washers and lock washers

(items 9,10,11) into the motor face. securely tighten bolts.

3. lubricate o-ring of self-sealing bolt (item 6) with suitable,

compatible lubricant. Insert self-sealing bolt through shipping

plug and into the eye of the impeller using a 9/16” deep well

socket. Insert a screwdriver into the motor fan to prevent

motor shaft from rotating. Tighten the bolt to 12-ft lbs.

4. remove the shipping plug from the suction port.
5. rotate the motor fan by hand and check for impeller rubbing.

If the impeller rubs, verify that the self-sealing bolt is properly

installed.

6. Proceed to the “Installation” section of these instructions.

InsTallaTIOn

MOUnTIng

Motor or base plate must be securely fastened.

PIPIng TO anD frOM ThE PUMP:

• always support the piping near the pump to minimize

stress and strain on the pump’s casing.

AC6 & AC8 HORIZONTAL SERIES

Sealed Metallic Centrifugal Pumps

Installation and Maintenance Instructions

Advertising