Insufficient pressure, Troubleshooting warranty, Temperature classification – Finish Thompson AC 6 & 8 HORIZONTAL SERIES User Manual

Page 6

Advertising
background image

nO Or InsUffIcIEnT flOW:

1. Pump not primed.
2. closed valve.
3. Viscosity too high.
4. air leaks in suction piping.
5. Discharge head higher than anticipated.
6. suction lift too high or insufficient nPsh.
7. check for clogged suction line.

InsUffIcIEnT PrEssUrE:

1. air or gas in liquid.
2. Impeller diameter too small.
3. Discharge head higher than anticipated.
4. Motor speed insufficient (too low) or rotation incorrect.

lOss Of PrIME:

1. leaking suction line.
2. foot valve or suction opening not submerged enough.
3. foot valve too small or leaking.
4. air or gas in liquid.
5. foreign matter in impeller.

EXcEssIVE POWEr cOnsUMPTIOn:

1. head lower than rating. Excessive flow.
2. specific gravity or viscosity of liquid is too high.

EXcEssIVE VIBraTIOn:

1. loose piping or bolts.
2. Pump cavitating from improper suction or feed.

call our toll free Technical service hot line, 1-800-888-3743, if you

have any questions regarding product operation or repair.

for further information, contact finish Thompson Inc. or your local
distributor.

Part No. J103532, Rev. 9
Literature ID No.FT00-793G, 10-31-08

TrOUBlEshOOTIng

WarranTy

finish Thompson, Inc (manufacturer) warrants this pump product to be

free of defects in materials and workmanship for a period of one year

from date of purchase by original purchaser. If a warranted defect, which

is determined by manufacturer’s inspection, occurs within this period, it

will be repaired or replaced at the manufacturer’s option, provided (1) the

product is submitted with proof of purchase date and (2) transportation

charges are prepaid to the manufacturer. liability under this warranty is

expressly limited to repairing or replacing the product or parts thereof

and is in lieu of any other warranties, either expressed or implied. This

warranty does apply only to normal wear of the product or components.

This warranty does not apply to products or parts broken due to, in whole or

in part, accident, overload, abuse, chemical attack, tampering, or alteration.

The warranty does not apply to any other equipment used or purchased in

combination with this product. The manufacturer accepts no responsibility

for product damage or personal injuries sustained when the product is

modified in any way. If this warranty does not apply, the purchaser shall

bear all cost for labor, material and transportation.
Manufacturer shall not be liable for incidental or consequential damages

including, but not limited to process down time, transportation costs,

costs associated with replacement or substitution products, labor costs,

product installation or removal costs, or loss of profit. In any and all

events, manufacturer’s liability shall not exceed the purchase price of the

product and/or accessories.

OrDErIng sParE ParTs:

spare parts can be ordered from your local distributor. always refer to

pump model number to avoid error.

OThEr fTI PrODUcTs:

Drum Transfer Pumps

ar

e available in sanitary construction, stainless

steel, polypropylene and cPVc. flows to 40 gpm, discharge heads to 80

feet and viscosities to 15,000 cps.
Portable Mixers for turbine mixing and blending handle viscosities to

1,000 cps with gentle, non-vortex circulation. available in 316 stainless

steel construction.
sealed centrifugal Pumps in gf polypropylene and cf PVDf come with a

wide variety of sealing materials. flows to 250 gpm, discharge heads to

130 feet and temperatures to 200

o

f (93ºc).

sealless Mag Drive centrifugal Pumps in gf polypropylene and cf PVDf.

flows to 250 gpm and discharge heads to 135 feet. handles temperatures

up to 220°f and have 30-minute run-dry capability. Mounts to standard

frame motors

.

aDDITIOnal InfOrMaTIOn

safETy PrEcaUTIOns fOr aTEX PUMPs

WarnIng: Proper materials of construction must be chosen

for the fluid being pumped. Improper material selection could lead

to pump failure and leakage. This is the responsibility of the end

user.

WarnIng: aTEX pumps must have a power monitor, flow switch,

pressure switch or similar device installed to protect against running

dry, closed discharge valve, major leaks, and possible sources of

ignition due to motor bearing failure. any of these conditions could

lead to a rise in surface temperature of the pump. The device must be

set to stop the pump within three seconds of a fault.

WarnIng: The pump must be checked for leaks on a regular

basis. If leaks are detected, the pump must be repaired or replaced

immediately.
WarnIng: The pump must be cleaned on a regular basis to avoid

dust buildup greater than 5mm.

TEMPEraTUrE classIfIcaTIOn

Pump temperature is completely dependent on operating conditions.

Pump will transfer heat from the piping system, motor, and fluid.

These items must be considered as a system when assessing an

aTEX application.

Advertising