Rma-303 direct charge - introduction – Ransburg RMA Direct A12867 User Manual
Page 15

RMA-303 Direct Charge - Introduction
LN-9266-11.3
12
Mechanical (Continued)
Shaping Air #2 (SAO) Supply:
Variable (See “Pressure Flow Data Charts” in the
“Introduction” section.)
Brake Air Supply (Nominal):
60-100 psig (414-689 kPa)
Maximum Fluid Pressure Supply
Paint:
200 psi (1379 kPa)
Solvent:
150 psi (1035 kPa)
Fluid Flow Rate:
25-700 cc/min. (300 cc/min. maximum for 30mm Bell Cup)
Bell Cup Cleaning Time
(Internal/External):
2.7 sec. (approx.)
Color Change Time:
Dependent on system configuration, fluid pressures, fluid
viscosity, fluid line lengths, etc.
Speed Readout:
Magnetic pick-up, unidirectional fiber optic transmission
Atomizer Replacement Time:
Less than 5 min.
Bell Cup Replacement Time:
Less than 2 min.
Minimum Control Equipment
Requirements:
(Versions listed or higher)
MicroPak LECU5004-17 (V.3.84)
Atomizer Module A11925-00 (V.0.4)
I/O Module A11435-00 (V.1.4) (0.01V) (4-20 mA)
* Specifications and ratings based on testing at sea level standard conditions.