RMA-303 Direct Charge - Introduction

LN-9266-11.3

12

Mechanical (Continued)

Shaping Air #2 (SAO) Supply:

Variable (See “Pressure Flow Data Charts” in the

“Introduction” section.)

Brake Air Supply (Nominal):

60-100 psig (414-689 kPa)

Maximum Fluid Pressure Supply

Paint:

200 psi (1379 kPa)

Solvent:

150 psi (1035 kPa)

Fluid Flow Rate:

25-700 cc/min. (300 cc/min. maximum for 30mm Bell Cup)

Bell Cup Cleaning Time

(Internal/External):

2.7 sec. (approx.)

Color Change Time:

Dependent on system configuration, fluid pressures, fluid

viscosity, fluid line lengths, etc.

Speed Readout:

Magnetic pick-up, unidirectional fiber optic transmission

Atomizer Replacement Time:

Less than 5 min.

Bell Cup Replacement Time:

Less than 2 min.

Minimum Control Equipment
Requirements:

(Versions listed or higher)

MicroPak LECU5004-17 (V.3.84)

Atomizer Module A11925-00 (V.0.4)

I/O Module A11435-00 (V.1.4) (0.01V) (4-20 mA)

* Specifications and ratings based on testing at sea level standard conditions.