Rma-303 direct charge - installation, Air filtration requirements – Ransburg RMA Direct A12867 User Manual

Page 42

Advertising
background image

RMA-303 Direct Charge - Installation

39

LN-9266-11.3

Ransburg Filter
Model No.

Description / Specifications

Replacement Ele-
ment Part No.

HAF-503

Pre-filter, removes coarse amounts of oil, moisture
and dirt. Used upstream of HAF-508 pre-filter
(used in systems with poor air quality.

HAF-15 Element One

HAF-508

Pre-filter, coalescing type, 136 SCFM, 98.5% effi-
ciency particulate removal .3 to .6 micron, max.
aerosol passed 1.0 micron, max. solid passed .4
micron (dependent upon SCFM requirement per
applicator, one HAF-508 can be used with up to
three RMA-303 assemblies).

HAF-38 Elements,
Carton of 4

RPM-418

Bearing air filter, coalescing type,19 SCFM,
99.995% efficiency particulate removal .3 to .6 mi-
cron, max. RMA-303 passed .6 micron max. solid
passed .2 micron (one per RMA-303

)

RPM-33 Elements,
Carton of 8

AIR FILTRATION REQUIREMENTS

Air must be properly filtered to ensure ex-
tended turbine life and to prevent contami-
nation of the paint finish. Air which is not
adequately filtered will foul the turbine air
bearings and cause turbine failure. The
correct type filters musts be used in an
RMA-303 system. The filter elements
must be replaced regular schedule to as-
sure clean air.

It is the user’s responsibility to ensure
clean air at all times. Turbine failure re-
sulting form contaminated air will not be
covered under warranty. If other filters are
incorporated in the system, the filters to
be used must have filtering capacities
equal or better than those shown in “Air
Filtration Requirements Charts.”

The user must ensure the bearing air sup-
ply is not inadvertently turned off while the
RMA-303 air motor is turning. This will
cause air bearing failure.

!

C A U T I O N

Each applicator must have its own filter
for bearing air. Recommended: RPM-418
or equivalent.

N O T E

Advertising