RMA-303 Direct Charge - Maintenance

63

LN-9266-11.3

Bell Cup Handling

Always verify that high voltage is turned off
and the atomizer bell has stopped spinning
before performing any type of handling mainte-
nance.

Bell Cup Replacement

Bell cup wear is dependent on many factors
such as bell speed, flow rate, and type of coat-
ing being applied.

The bell cups shown in the photos indicates if

Photo 1

a bell cup has some useable life or should be
replaced. Photo 1 shows a bell cup that has
some useable life. The grooves worn around
the splash plate pins are shallow. The general
appearance of the cup surface is smooth and
uninterrupted. Photo 2 shows a bell cup that
needs to be replaced, as well as the splash
plate that was installed into the cup. The
grooves are deep, a visible groove exists at the
outer edge diameter of the splash plate and
there are noticeable lateral grooves extending
towards the outer edge of the cup.

Photo 2