RMA-303 Direct Charge - Maintenance

71

LN-9266-11.3

Splash Plate Insertion

Shroud Removal / Replacement

Removal

Remove five (5) screws from back of applica-
tor. Remove break-away ring and quick dis-
connect ring. Pull shroud off.

Shroud Removal

Replacement

Push the shroud back into place. A light tap
on the end may be required to seat the shroud
in position. Slide the quick disconnect ring
over the shroud.

Reinstall break-away ring by aligning the four
(4) holes with the dowel pins on the recessed
face of the rear manifold. Reinstall the five (5)
stainless steel screws. Tighten evenly to 15-
20 lbs•in (1.69-2.26 Nm) torque. If you are
using the optional plastic break-away screws,
tighten evenly to 5 lbs•in (.56 Nm) torque. The
break-away rig must lie flat against the face of
the rear manifold.

!

C A U T I O N

DO NOT over-tighten the five (5) optional

plastic break-away screws or they may
break under normal operating conditions.

Inner / Outer Shaping Air Manifold, Solvent
Tube Removal / Replacement

Air Manifold Removal

Remove the outer shaping air manifold by
turning it off by hand in a counter-clockwise
direction. A strap wrench may also be used.
Remove the fitting, ferrule, and external cup
wash line from the inner shaping air manifold
by turning the fitting in a counter-clockwise di-
rection using a 3/16” end-wrench. Loosen set
screw (A11253-00) on inner shaping air mani-
fold with a 5/64” hex-wrench enough to allow
manifold to be removed from the turbine body.
Remove the inner shaping air manifold by
turning it off in a counter-clockwise direction
(see “Inner/Outer Shaping Air Manifold, Sol-
vent Tube Removal/Replacement” figure).