RMA-303 Direct Charge - Maintenance

67

LN-9266-11.3

DISASSEMBLY PROCEDURES

For reassembly instructions, use the reverse of
the following disassembly procedures.

To facilitate atomizer removal from hose mani-
fold, a robot program should be made that
purges all paints and solvents from the RMA-
303. Ideally it would then position the bell as-
sembly in a bell removal position where the
bell cup is pointed downward at a 30° angle.
Any residual solvents would be contained in
the “J bend “ of the robot wrist.

All O-rings described in the “Maintenance” sec-
tion of this manual should be lubricated with a
food grade petroleum jelly or with A11545 lub-
ricant.

Atomizer Removal / Replacement

Using the applicator removal tool (76772-00)
insert the pin diameter of the wrench into one
of the four (4) holes of OD of the quick discon-
nect ring. Apply a force to the tool in a counter
-clockwise direction as shown in “Applicator
Removal from Robot” figure.

N O T E

Applicator Removal from Robot

!

W A R N I N G

Prior to removing applicator from the ro-

bot, the following tasks must be complet-
ed.

- Robot put into E-stop mode, locked and
tagged out.

- All fluid passages are cleaned, purged
out, and depressurized.

- Air turned off.

!

W A R N I N G

Carefully remove the quick disconnect

ring to ensure any residual line pressure
has been relieved to atmosphere.

Bell Cup Removal / Replacement

The bell cup should always be the first compo-
nent removed if any maintenance is per-
formed. Following the procedure will minimize
the risk of damage to the cup.

Lay the applicator on its side of a clean and
secure area, preferably an area where irregu-
lar maintenance is performed. Using the large
open end of the bell cup / combo wrench
(A12061-00) on the flats of the turbine shaft,
carefully hold the outside of the bell cup with
one hand while applying a clockwise force to
the wrench. The bell cup is a right hand
thread and must be turned counter-clockwise
to remove.

Place the bell cup in a safe and secure place.
Carefully inspect the cup for any damage. If
there is any damage to the cup, it must be re-
placed.

N O T E