Ransburg, Specifications, Environmental/physical – Ransburg Discrete IO Module A11435 User Manual

Page 10: Electrical, Electrical (cont.), Discrete i/o module - safety

Advertising
background image

SPECIFICATIONS

Environmental/Physical

Operating Temperature:

0°C to 55°C

Storage Temperature:

-40°C to 85°C

Humidity:

0 to 95% non-

condensing

Size:

100 X 160 mm

Eurocard

Module,

1

inch

wide

Electrical

Electrical Power

Required:

24 VDC @ 0.11 A or

28 VDC @ 0.10 A

I

nput current does not include that required by

analog and digital outputs. 24 VDC and 28 VDC

must be regulated and have over-current (40%) and

over-voltage (20%) protection.

Electrical I/O:

(Connection points listed in Tables 1, 2, 3, and 4)

Analog In:

(0-10 VDC or 4-20 mA)

kV

Set

Current Set (Over-Current

Setpoint)

Atomizer

Speed

Set

Di/dt

Set

Analog Out:

(0-10 VDC or 4-20 mA)

Output

kV

Output

Current

Atomizer

Speed

Atomizer

Drive

Pressure

Electrical (Cont.)

Digital In:

(24 VDC Source or Sink)

HV

On

HV

Off

Fluid

Trigger

Air

Trigger

Di/dt

Disable

Bell

Spin

Enable

Digital Out:

(Dry Contact)

Bell

Running

HV

Ready

HV

On

Over-Current

Fault

Feedback

Fault

Analog Input In Local

Overspeed

Fault

Underspeed

Fault

Loss

of

Feedback

Invalid

Speed

Command

Low

Bearing

Air

Fault

Speed

Out

of

Tolerance

Discrete I/O Module - Safety

7

LN-9253-06.1

Ransburg

Advertising