Analog Inputs

0-10 VDC or 4-20 mA set by position 8 of SW2. In 0 to 10 VDC mode (SW2-8 down), input impedance

is 150 kohm. In 4 to 20 mA mode (SW2-8 up), input impedance is 500 ohm.

Analog Outputs

(3 mA maximum for 0-10 VDC outputs, 20 VDC maximum for 4-20 mA outputs)

The four analog outputs in this table are individually settable for either 0-10 VDC or 4-20 mA outputs.

the Down position of the Mode Control switch is for 0-10 VDC. The Up position is for 4-20 mA.

High Voltage Output Level, 0-100 kV
High Voltage Output Ground
Current Output Level (See "Figure 1 - Required
Dipswitch Setting" for scaling)
Current Output Ground
Atomizer Speed Feedback (See "Figure 1 -
Required Dipswitch Setting" for scaling)
Speed Feedback Ground
Drive Pressure Feedback, 0-100 psi
Drive Pressure Ground

TABLE 2 - ANALOG OUTPUTS

GRN

BLA

WH

BLA

RED

BLA

BLA/RED

BLA

Wire Color

Description

14C

17A

6C

8A

7C

7A

8C

7A

Pin #

Mode

Control

SW6

SW5

SW3

SW4

High Voltage Setpoint, 0-100 kV
High Voltage Set Ground
Overcurrent Setpoint (See "Figure 1 - Required
Dipswitch Setting" for scaling)
Overcurrent Setpoint Ground
Speed Setpoint, 0-50 or 0-100 krpm
Speed Setpoint Ground
Di/Dt Sensitivity 0-9 Scale (0 is most sensitive)
Di/Dt Sensitivity Ground

TABLE 1 - ANALOG INPUTS

YEL
BLA

BLU

BLA

BRN

BLA

WHT

BLA

Wire Color

Description

5A

28C

6A

28A

4C

3A

3C

28A

Pin #

Discrete I/O Module - Safety