Discrete Outputs

(Contact ratings: 2 A @ 28 VDC resistive, 0.5 A @ 120 VAC resistive, one side common with 30C)

High Voltage On - Indicates High Voltage is On
High Voltage Ready - Indicates interlock is satisfied, High Voltage
Reset is not active, and no Faults are present
Overcurrent Fault or Di/dt Fault - Indicates that either the
Overcurrent Fault or Di/dt Fault has occurred.
Feedback Fault - Indicates abnormal signal levels are present on
the kV and/or Current feedback signals from the cascade. (See
the "Diagnostic" section in the current MicroPak service manual.)
Local - Indicates front panel switch is in "Local" position.
Bell Running - Indicates that the Serial Atomizer Module is
supplying Drive air pressure to the bell
Overspeed Fault - Indicates module has shut-down drive to bell
because speed is above Overspeed setpoint.
Underspeed Fault - Indicates module has shut-down drive to bell
because speed is below underspeed setpoint.
Loss of Feedback Fault - Indicates module has shut-down drive
to bell because it detects no feedback pulses.
Invalid Setpoint Fault - Indicates module has shut-down drive to
bell because setpoint is above the operating range for the bell.
Low Bearing Air Fault - Indicates module has shut-down drive to
bell because bearing air is too low for this bell
Speed Out of Tolerance - Indicates bell speed is outside the
window of ±5% of setpoint. this is a status signal only and does
not shut-down drive to bell.
24 VDC utility output, may be used to power relay contact
common on Pin 30C, 0.1 A maximum.

TABLE 4 - DIGITAL OUTPUTS

GRN/BLA

ORG/RED

BLA/WH/RED

ORG/GRN

RED/WH

RED

BLA

GRN

BLU

BLA/WH

GRN/WH

GRN/BLA/WH

RED/BLA/WH

Wire Color

Description

27C
26C

24A

22A

22C

26A

1A

4A

12A

23C

24C

25C

31A

Pin #

Discrete I/O Module - Safety

11

LN-9253-06.1

Ransburg