Ransburg – Ransburg Discrete IO Module A11435 User Manual

Page 13

Advertising
background image

Digital Inputs

24 VDC source (SW7, 8 Up) or sink SW7, 8 Down)

Ground Reference 18A, 14A, or 13A.

High Voltage On - If High Voltage Ready is active,
causes high voltage to be present at cascade
output
High Voltage Reset - Turns off High voltage, over-
riding High Voltage ON signal, also reset faults
conditions
Fluid Trigger - Causes Fluid Trigger to MicroPak to
be active
Air Trigger - Supplying 24 VDC causes air trigger to
EFM gun to be active.
Di/dt Inhibit - Supplying 24 VDC causes di/dt to be
disabled.
Bell Spin Enable - Causes speed setpoint to be
sent to Serial Atomizer Module, also used for fault
reset

BLU/BLA

ORG/BLA

RED/BLA

WH/RED

ORG

BLU/WH

Wire Color

Description

20C

19C

17C

16C

15C

9C

Pin #

Source/Sink

Control

SW7

SW7

SW7

SW7

SW8

SW8

TABLE 3 - DIGITAL INPUTS

Discrete I/O Module - Safety

10

LN-9253-06.1