INSTALLATION
CONNECTIONS
See "Connections from Computer Serial Port to
Discrete I/O RJ12 Terminal Connector" in the
"Maintenance" section.
INPUT POWER
This must be supplied from a regulated power sup-
ply. Either +24 or +28 VDC may be used. When
using the LECU4014 motherboard make connec-
tions to J10. When using the 78145 motherboard
make connections to J8.
I/O SIGNALS
The following I/O signals are avilable for control
and monitoring of one MicroPak and/or one Serial
Atomizer Module. Connections must be made
with 76111-XX cable assembly plugged into the
motherboard. Wire colors shown in the tables
below refer to that cable assembly.
NOTES
Discrete I/O Module - Safety
8
LN-9253-06.1