Operation, Ransburg, Main menu – Ransburg Overhead Electric Reciprocator ER-8100 User Manual

Page 15: Run mode, Electric overhead reciprocator - operation

Advertising
background image

MAIN MENU

The MAIN MENU screen is used to access all

other sub-menus. From the main menu, other

menus are accessed using the function keys. The

list of sub-menus may be viwed using the up and

down arrow keys. It is not, however, necessary

to have the required sub-menu in view to select

it. Throughout the entire menu structure, the F12

function key is used to return to the main menu.

OPERATION

RUN MODE

The menu for RUN MODE is selected from the

MAIN MENU using the F1 key. The selections

under Run Mode determine the type of Program

which will be run. A Program is a sequence of

points and associated velocities, digital outputs

(2), and analog outputs (1). A program may

have from two to eight points. Shown below is

a description of a program with four points. The

program is run by the reciprocator in the forward

direction (Point 1 to 2 to 3 to 4) at the velocity

specified at the start of a segment. The digital

and analog outputs are also set as specified at

the starting point of the segment. At the last point

the sequence is reversed. The program is run in

the reverse direction (Point 4 to 3 to 2 to 1). In

order to maintain the same velocity, and digital

and analog outputs, while running in the reverse

direction, the values from the end point of each

segment must be used for that segment.

Point 1: 7” @ 30”/sec

Dig1:0

Dig2:0

Analog: 0

Point 2: 35” @ 15”/sec

Dig1:1

Dig2:0

Analog: 60

Point 3: 50” @ 30”/sec

Dig1:1

Dig2:0

Analog: 0

Point 4: 97” @ 30”/sec

Dig1:1

Dig2:0

Analog: 0

Point 5: 0”

12

Electric Overhead Reciprocator - Operation

Ransburg

LN-9801-05.1

Advertising