background image

Enclosure Data

A = Largest Part Dimension Across

Conveyor (Rotating or Indexing

Diameter)

R = Minimum Conveyor Loop Radius

Rb = Minimum Booth Radius (Inside)

D = Conveyor Loop Diameter

Db = Booth Diameter (Inside)

T = Standard Conveyor Throat Opening for a

Highly Conductive or Waterborne System

Tb = Booth Throat Opening (Width)

M = 9-inch from the edge of part or 18-inch

from center line of conveyor to enclosure

wall (whichever is greater).

H = Booth Height

>

Booth Height is the same as Conveyor

Height.

NOTE

Reciprocator Stroke Speed

Reciprocators are available in stroke speed 1 In/

Sec. - 5 Ft/Sec. Speeds should be specified to

provide minimum of four passes in loop. The fol-

lowing is used to determine required stroke speed:

L = Line Speed In Ft/Minute

F = Length of conveyor in loop, in feet

D = Dwell time of part in loop, in

seconds

S = Stroke length

R = Reciprocator speed required in

feet/second

Formula:

60 X F = D

L

D = R

S X 4

Booth Exhaust Air Volume (DFM) Require-

ments

Formula:

Tb X H = Sq/Ft of Booth Opening

144

Sq/Ft of Booth Opening +

nRb

= Total Sq/Ft of

12 Booth Opening

Total Sq/Ft of Booth Openings X 75 RPM = CFM

This calculation provides for an air exchange

through the booth @ 6-7 times per minute.

36

Electric Overhead Reciprocator - Maintenance

Ransburg

LN-9801-05.1

Advertising