Magnalock preparation and installation – Securitron M680 User Manual

Page 2

Advertising
background image

PN# 500-10550

Page 2

Rev. C, 08/12

Recommended Tools

M670 / M680BD Specifications

Mechanical

Electrical

Environmental (Recommended)


Physical Size
:
Height: 2-1/2” [66mm]
Depth: 2-1/2” [66mm]
Length: 11-1/2” [292mm]


Shipped Weight
:
Weight: 13 lbs

Holding Force (Maximum)
1,100 Lbs. [500kg]


Input Voltage

12/24 VDC

Current

M670
12VDC/575mA (±10%)

24VDC/275mA (±10%)
M680BD
12VDC/550mA (±10%)

24VDC/300mA (±10%)

Tamper Switch Rating
Voltage – 30VDC (Maximum)
Current – 1 Amp
DPS Rating (M680 only)
Voltage – 30VDC

(Maximum) Current – 125mA


Operating Temperature

32ºF to 110ºF [0ºC to 43ºC]

Humidity
10% to 90% RH



Magnalock Preparation and Installation


Pre-Installation Survey

Before installing the Magnalock, the mounting location should be determined and assessed for the
following:

Physical strength of the frame should be strong enough to meet or exceed the holding force of
the Magnalock

Frame and vicinity should offer protection for the wiring to prevent vandalism

Door should be inspected for any obstacles that may interfere when mounting the strike plate

The Magnalock M670/M680 comes with factory default mounting for use with an outswing door.
Please contact Securitron for available brackets for other installation configurations.



Masking Tape

#0, #1 and #2 Phillips Screwdrivers

Hammer

Measuring Device

1/2” Open End or Crescent Wrench

Pencil/Pen

Center Punch

Wire Strippers/Cutter

Multimeter

Fish Tape or Lead Wire

3/16” Hex (Allen) Wrench

Drill bits: 3/16”, 7/32” (wood frames only), 3/8”, 1/2”

Advertising