SFP – Stop Filler Plate – The SFP bracket is designed for extending the door frame

mounting surface 1-1/4” [31.8mm]. Thicknesses available in 1/4” [6.4mm], 3/8”
[9.5mm], 1/2” [12.7mm] and 5/8” [15.9mm]. Lengths available in 8” [203mm] for M32

or M62 and 12” [305mm] for M82B Magnalocks.

UHB – Universal Header Bracket The UHB bracket is designed to extend the frame

width 1” [25.4mm] to 1-1/2” [38.1mm] deeper on steel and aluminum headers not wide
enough to mount the Magnalock. Lengths available in 8” [203mm] for M32 or M62 and
12” [305mm] for M82B Magnalocks.

Z-Bracket The “Z” bracket is designed for use with installations of “F” Series

Magnalocks for in-swinging doors and gates.

ZA-Bracket – The “ZA” bracket is designed to allow a full range of adjustability for use

with installations of “F” Series Magnalocks for in-swinging doors and gates.

7. SPECIALIZED STRIKES

 The AOS Armature Offset strike is designed for offset drilling doors with mechanical

interference hardware present in the door structure. It is also accommodates errors that
may have occurred in the field from incorrect mounting placement. (See Section 5.2.5)

 The ASS – Armature Split strike is designed for single lock/double door installation. There

is a reduced holding force when using the split strike. (See Section 5.2.5)

8. SPECIALIZED ACCESSORIES
8.1

Dress Covers

Single Magnalock Dress Covers – The covers are designed to meet architectural

finishes for matching specified installations. Available in four (4) architectural finishes.

Double Dress Covers – The covers are designed to fit over a double door/dual lock

installation. Available in two (2) architectural finishes.

8.2 Installation Tool Kit Securitron offers an installation tool kit which includes special drill

bits, a heavy duty drill guide, a blind nut collapsing tool, extra fasteners and hardware.
Metric is also available.

8.3 Tamper Proofing Special tamper proof screws are available for Magnalock and strike

armature mounting. The screws are pinned-socket hex head. A special hex wrench is
required and is available when purchasing the screws.

9. MAGNALOCK MAINTENANCE
9.1 Visual Inspection

 Check the rubber washers for elasticity and proper pivoting. Tighten as required.

 Check for build-up of debris on the Magnalock and strike armature. Clean as required.

 Check for rust on the Magnalock and strike plate armature. Clean as required.

9.2 Cleaning Methods

 Cleaning once a year is recommended.

 Clean every six months where minor rusting occurs.

 Clean every three months if rust conditions are severe.

 Use a plastic dishwashing scrub pad to aid in the removal of rust.

DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING

DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER

9.2.1

Indoor Applications

 Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and

strike plate armature.

9.2.2

Outdoor Applications

 Apply a silicone based cleaner/lubricant onto a clean cloth and thoroughly wipe down

Magnalock and strike plate armature.
Example: Super Lube® Aerosol with SYNCOLON® (PTFE)

Part No.: 31040 ~ 6oz. / 31110 ~ 11 oz. / 32015 ~ 14 oz.
Phone: (631) 567-5300 / Website: www.super-lube.com