4. RECOMMENDED TOOLS

Power Drill

Hammer

Wire Strippers/Cutter

1/8”, 3/8”, 1/2” Drill Bits

Center Punch

Crimp Wire Connectors

1/2” Open end or Crescent Wrench

Masking Tape

Crimp Tool

3/16” Hex Key (Allen Wrench)

Fish Tape or Lead Wire

Multimeter


5. INSTALLATION INSTRUCTIONS
5.1 Pre-Installation Survey
It is recommended that an initial on sight survey be performed. A method of mounting should

be determined and an installation plan should be reviewed as follows:

 Physical strength of mounting areas should be strong enough to meet or exceed the

holding force of the required Magnalock.

 Placement of the Magnalock wiring and protection from potential damage due to intruders

or vandals external attack should be considered during the survey.

 Accessibility should be considered for prevention of any potential safety hazard.

Additional brackets may be needed for proper installation. Specialized brackets are available
through Securitron and their many product distributors. (Section 6)

5.2 Out-Swinging Door
The installation shown below in Figure 2 illustrates the door swinging away from the Magnalock.

This is a common configuration on the secure side of exit doors. The Magnalock mounts to the
door frame header near the corner opposite the hinge side. The Magnalock may be mounted
horizontally or vertically depending on the installation required. The brackets shown in Figure 2
are to assist installation to door frames that may need modifications to complete the installation.

Figure 2

Dress Plugs

Mounting Screws

Sex Bolt & Strike

Mounting Screw

Door Frame & Stop

Rubber Washers

Door

Strike Plate

Flat Washers

Blind Nuts

Magnalock

UHB Bracket

SFP Bracket

M32 ~ 2-1/4”
M62 ~ 2-1/2”

M82 ~ 2-1/2”

Advertising
This manual is related to the following products:

M62, M32