Important – Securitron M82B User Manual

Page 6

Advertising
background image

PN#

500-10420

Page

6

Rev. F, 02/11

Single Lock - Double Door Magnalock Mounting

A single Magnalock can be used to secure double doors using a split strike plate. The part
numbers reduction of holding force for each model is listed below in Table B. Use the template

and instructions provided with the split strike package for proper installation. (See Section 7)







Table B


5.2.3

DM62 Double 62 Magnalock

The DM62 consists of two (2) Model 62 Magnalocks arranged in one (1) stainless steel housing
as shown in Figure 8. This product individually secures out-swinging double door applications.

Figure 8


Use the template diagram installation instructions included with the DM62 Magnalock assembly.
The features to consider during the installation procedure:

 Position the Magnalock centered between the doors.

 The mounting diagram measurement and marking placement are critical.

 The mounting diagram is NOT a scaled template.

 Refer to the Magnalock out-swinging door mounting procedures in Section: 5.2.

 Refer to the strike mounting procedures in Section: 5.2.1.

 Refer to the blind nut instructions in Section: 5.2.3.

5.2.4

Mounting Magnalocks for Gates

The “G” Series Magnalock is suitable for use on outdoor gates. Figure 9 illustrates a variety of
typical gate operations for application types and installation techniques. Special mounting
brackets are available. See Section 6.2 for gate bracket information.

IMPORTANT

THE STRIKE PLATE SHOULD NOT BE WELDED DIRECTLY TO THE GATE

THE STRIKE MUST BE MOUNTED USING THE HARDWARE PROVIDED

HOLDING FORCE AND ALIGNMENT WILL OTHERWISE BE AFFECTED

Model Offset Strike

Part Number

Split Strike

Part Number

Holding Force

(per leaf)

M32

N/A

ASS-32

230 lbs. [104 kg]

M62

AOS-62

ASS-62

550 lbs. [250 kg]

M82

AOS-82

ASS-82

850 lbs. [385 kg]

Advertising
This manual is related to the following products:

M62, M32