6.5 Electrical Wiring
The following diagrams, Figures 17, 18, 19 and 20 represent the proper electrical wiring
connections required for SAM Magnalock Standard, and for SAM BondSTAT “B”, DPS “D” and

“BD” versions.

_

+

NC

+

C

NO

RED

_

BLK

SAM STANDARD

VERSION

2-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

DC

POWER

SUPPLY

120

VAC

INPUT

*12/24

VDC

OUTPUT

Figure 17

NC

+

C

NO

NC

RED

_

C

NO

WHT

GRN

ORG

BLK

LOCK

STATUS

REF.

SAM SERIES "B"

BondSTAT VERSION

5-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

LOCK

STATUS

_

+

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

Figure 18

NC

+

C

NO

REF.

NC

RED

_

C

NO

YEL

BLU

BRN

BLK

SAM SERIES "D"

DPS VERSION

5-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

DOOR

STATUS

_

+

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

Figure 19

NC

+

C

NO

REF.

REF.

NC

RED

_

C

NO

NO

NC

C

WHT

GRN

ORG

YEL

BLU

BRN

BLK

SAM SERIES "BD"

BondSTAT/DPS VERSION

8-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

LOCK

STATUS

DOOR

STATUS

_

+

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

Figure 20