Securitron SAM User Manual

Page 13

Advertising
background image

PN# 500-10440

Page 13

Rev. F, 02/12

8 MAGNALOCK MAINTENANCE
8.1 Visual Inspection

 Check the strike assembly for proper gap, suspension and free movement. Tighten strike

adjustment screws as required.

 Check for build-up of debris on the Magnalock and strike armature. Clean as required.

 Check for rust on the Magnalock and strike assembly. Clean as required.


8.2 Cleaning Methods

 Cleaning once a year is recommended.

 Clean every six months where minor rusting occurs.

 Clean every three months if rust conditions are severe.

 Use a plastic dishwashing scrub pad to aid in the removal of rust.

DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING

DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER


8.2.1 Indoor Applications

 Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and

strike plate armature.


8.2.2 Outdoor Applications

 Apply a silicone based cleaner/lubricant onto a clean cloth and thoroughly wipe down

Magnalock and strike plate armature.
Example: Super Lube® Aerosol with SYNCOLON® (PTFE)

Part No.: 31040 ~ 6oz. / 31110 ~ 11 oz. / 32015 ~ 14 oz.
Phone: (631) 567-5300 / Website: www.super-lube.com


APPENDIX A

Troubleshooting

Problem

Lock Does Not Generate a Magnetic Field

Points of Reference

Check for specified voltage at Magnalock Section

2

Solution

Check for specified current draw at Magnalock

Section 2

Problem

Reduced Holding Force

Points of Reference

Check DC power source is Full-Wave Rectified

(Half-wave Rectifier or AC Power unacceptable)

Section 6.2

Check for specified voltage at Magnalock Section

2

Check for specified current draw at Magnalock

Section 2

Check strike mounting for proper installation

Sections 5.6-5.7

Solution

Check the Magnalock and strike for obstructions

and that contact surfaces are properly cleaned

Section 8

Problem

BondSTAT Does Not Report Secure

Points of Reference

Check for specified voltage at Magnalock Section

2

Check for specified current draw at Magnalock

Section 2

Check strike mounting for proper alignment and

pivoting for proper closure to Magnalock

Table A / Section 5.6.6

Solution

Check the Magnalock and strike for obstructions

and that contact surfaces are properly cleaned

Section 8







Advertising