Securitron DKC User Manual

Page 19

Advertising
background image

PN# 500-33510

Page 19

Rev. A, 06/13

Deleting all codes except Master, Supervisor, and Hard codes:
 Enter the master program code followed by the * key and the yellow LED will flash once per

second

 Enter 88* followed by # twice
 After less than 2 seconds the red LED will flash twice
 Exit programming mode by pressing either the * or # key and the yellow LED will stop

flashing

DKC Programming Options on the DKC CPU Board
1. Slide switch to select door to be programmed
2. Press push button switch SW2 until the desired code option is reached

0 for Master code (DK-37 DK-38)
1 for Supervisor code (DK-37 DK-38)

2 for Hard code
3 for Master Add Card (Wiegand only) – AKA: User Code Add
4 for Master Delete Card (Wiegand only) – AKA: User Code Delete
5 USB enable code
6 for Passage code

7 for Lockout code
8 for One-Time Use code
9 Learn Facility code (Wiegand only)

3. Yellow light on keypad will flash indicating DKC is in Programming Mode. Yellow light will

continue to flash until Programming Mode is exited or after a 30 second timeout period.

4. Enter the code at the keypad followed by * key. Red light flashes twice for a valid code entry.

Note: Master and Supervisor codes must be 5 to 7 digits, user codes must be 2 to 7 digits long
for DK-37 and DK-38

Technical Support
For general questions concerning this or other Securitron products please visit the Securitron
website www.Securitron.com or contact Securitron Technical Support at (800) 624-5625
or email [email protected]


MagnaCare Lifetime Replacement Warranty
For MagnaCare Lifetime Replacement Warranty information please visit:

www.securitron.com/en/site/securitron/About/MagnaCare-Warranty/