Adding Other Lock Control Switches
Sometimes other control switches are needed that are not appropriate for the REX input, as use
of this input triggers the timed release capability of the DKC. A typical example would be a
switch located centrally which would release the lock in response to an intercom call for
example. If the lock is fail safe, the switch will need to break power to the lock and if it is fail
secure, the switch will need to send power to the lock. Figure 5

shows how to add external

contacts for non-timed remote release of the lock for both lock types.

COM

ADDING EXTERNAL CONTACTS FOR FAIL SAFE AND FAIL SECURE LOCKS

Figure 5

NC

FAIL SAFE LOCK

FOR NON‐TIMED REMOTE 

RELEASE OF FAIL SAFE LOCK, 

PLACE NC CONTACTS IN 

CIRCUIT AS SHOWN

DC  

+

DC  

+

NO

NC

COM

FOR NON‐TIMED REMOTE 

RELEASE OF FAIL SECURE LOCK, 

PLACE NO CONTACTS IN 

CIRCUIT AS SHOWN

COM

NO

FAIL SECURE 

LOCK

DC  

+

DC  

+

COM

Connecting to ASSA ABLOY Aperio

TM

Products

Aperio

TM

technology is a global wireless platform that reduces the cost and inconvenience of

traditional access control – without the hassle of complex site surveys. It utilizes local wireless
communication between the lock and a communications hub to connect to an online electronic
access control system. This offers facilities an easy, affordable way to expand the reach of
existing access control systems and secure additional openings.

When using Aperio

TM

products with the DKC, an AH20 Aperio

TM

Wiegand Hub must be used.

Please note that the green/red light logic must be set to ‘Reverse’. Additionally the ‘Aperio hub’
option button must be selected on the ‘Keypad/Aperio Hub’ option for the associated door. These
options are selected in the Door Options tab in the DKC Programming Tool. Please note that
Passage mode CANNOT be used with an Aperio

TM

hub. Aperio

TM

products conform to higher

security requirements that do not allow passage mode to be used.

Wiring the Aperio

TM

hub to the DKC is shown in Table 3 and Figure 6.

DKC

Terminal

DKC Wiring Reference

Suggested
Wire Color

Aperio Hub

Terminal

+12V

Positive DC supply lead

Red

8-24V DC

D0

Wiegand data zero

Green

D0

D1

Wiegand data one

White

D1

LED-G Green

LED

Orange GREEN

LED-R Red

LED

Brown RED

(-) Ground

Black

GND

Table 3: Minimum Wiring Terminal Connections from DKC to Aperio hub