Table 1: dkc power consumption, Table 2: wiring terminal connections – Securitron DKC User Manual

Page 4

Advertising
background image

PN# 500-33510

Page 4

Rev. A, 06/13

DKC Power Consumption

12V

24V

DKC (excluding keypads)

250 mA

250 mA

DK-37 or DK-38 Keypad (each) 100 mA

100 mA

Electronic Lock

Consult lock manual

Consult lock manual

Aperio Hub (each)

250 mA

250 mA

Table 1: DKC Power Consumption


Connecting the Keypad Cable to the CPU Board
There are 9 color coded wires in the keypad cable. Refer to Figure 1 and Table 2 below and
connect each wire to the indicated terminal on the CPU board.

Overview of CPU Board

UC

D

D

OOR

P

OS

RE

X

HC

D

D1

DO

+

12V

LE

D

- Y

LE

D

-

R

LE

D

- G

( -

)

TA

M

P

BU

Z

E

XP

PO

R

T

USB

PORT

BA

TT

ER

Y

NO

NC COM

NO

NC COM

NO

NC COM

NO

NC COM

+

+

-

-

Door 1

Door 2

UC

D

D

OOR

P

OS

RE

X

HC

D

D1

DO

TA

M

P

BU

Z

DOOR 1

DOOR 2

OPTION 2

OPTION 3

12

-2

4V
A

C

/D

C

DC OUT 1 DC OU T 2

1A

1A

NO

NC COM

OPTION 1

Man Trap

Fa cility Only 2
Fa cility Only 1

+

F6 F1

F2

F3

F4

F5

Figure 1

M

A

IN

IN

( -

)

LE

D

- Y

LE

D

-

R

LE

D

- G

+

12V

+

12V

+

12V

J9

J8

J10

J11

DKC
Terminal

DKC Wiring
Reference

Suggested Wire
Color

DK-38
Terminal

+12V

Positive DC supply lead Red

DC+

D0

Wiegand data zero

Green

D0

D1

Wiegand data one

White

D1

LED-G Green

light

Orange

GRN

LED-R Red

light

Brown

RED

LED-Y Yellow

light

Blue

YEL

BUZ Audible

buzzer Yellow

BUZ

TAMP Tamper

indicator

Purple

TAMP

(-) Ground

Black

GND

Table 2: Wiring Terminal Connections


Note that suggested wire color for ‘LED-Y’ terminal is BLUE and suggested wire color for ‘BUZ’
terminal is YELLOW.

Power and Electric Lock Wiring
When using transformers or power supplies with the DKC, select a transformer or power supply
of the same voltage as the lock (12V or 24V).

Advertising