APPENDIX A

Troubleshooting

Problem

No Alarm when Testing Door Movement

Points of Reference

Check for specified voltage to unit Section

2

Check for specified current draw at unit

Section 2

Check magnetic actuator for proper mounting

iMXDa Template

Solution

Verify gap testing and training of unit

Section 6.4

Problem

Immediate Alarm when Testing Movement

Points of Reference

Check for proper door closure

Section 5.1 / Section 8

Check magnetic actuator for proper mounting

iMXDa Template

Check lock housing and strike for proper mounting

iMXDa Template

Make sure Jumper JP3 is in correct position

Section 6.3 (Figure 15)

iEXDa: Ensure that the circuit connected to the “EI”

terminal is properly functioning.

Section 6.3

Solution

iMXDa: Verify gap testing and training of unit

Section 6.4

Problem

Lock Does Not Generate a Magnetic Field

Points of Reference

Verify the Magnalock is connected to PCB

Section 6 (Figure 10)

Check for specified voltage at Magnalock

Section 2

Solution

Check for specified current draw at Magnalock

Section 2

Problem

Magnalock locks, but green LED does not illuminate

Points of Reference

Solution

(See Reduced Holding Force – below) -

Problem

Reduced Holding Force

Points of Reference

Check for specified voltage at Magnalock Section

2

Check for specified current draw at Magnalock

Section 2

Check strike for proper mounting

Section 5.1 / Template

Check the Magnalock and strike for obstructions

Section 5.1 / Section 8

Solution

Check Magnalock and strike are properly cleaned

Section 8

Problem

DPS Does Not Report Door Status

Points of Reference

Check strike mounting for proper alignment

Table A / Section 5.1

Check for proper door closure

Section 5.1 / Section 8

Check for proper voltage/current on switch

Section 2

Solution

Check resettable protection (polyswitch overload)

Section 2 (DPS)

Problem

The Magnalock is Dirty or Rusty

Points of Reference

Solution

Improper cleaning – Maintenance Equipment

Section 8

Problem

Electronic Noise Interference with

Access Control System

Points of Reference

Solution

Check for voltage from Magnalock to door frame. There

should be no voltage present.

Section 2

IF PROBLEMS PERSIST CALL SECURITRON TOLL FREE

(800) MAG-LOCK