Gilderfluke&Co DMX-512 Output MultiShow Brick User Manual

Page 22

Advertising
background image

Each J-6 cable is arranged in the following order:

wire number

color

wire function

1

brown

circuit ground

2

red

channel 0 data bit 7

3

orange

channel 0 data bit 6

4

yellow

channel 0 data bit 5

5

green

channel 0 data bit 4

6

blue

channel 0 data bit 3

7

violet

channel 0 data bit 2

8

gray

channel 0 data bit 1

9

white

channel 0 data bit 0

10

black

+15 VDC unregulated power supply (fused for 1 amp)

11

brown

circuit ground

12

red

channel 1 data bit 7

13

orange

channel 1 data bit 6

14

yellow

channel 1 data bit 5

15

green

channel 1 data bit 4

16

blue

channel 1 data bit 3

17

violet

channel 1 data bit 2

18

gray

channel 1 data bit 1

19

white

channel 1 data bit 0

20

black

+15 VDC unregulated power supply (fused for 1 amp)

21

brown

circuit ground

22

red

channel 2 data bit 7

23

orange

channel 2 data bit 6

24

yellow

channel 2 data bit 5

25

green

channel 2 data bit 4

26

blue

channel 2 data bit 3

27

violet

channel 2 data bit 2

28

gray

channel 2 data bit 1

29

white

channel 2 data bit 0

30

black

+15 VDC unregulated power supply (fused for 1 amp)

31

brown

circuit ground

32

red

channel 3 data bit 7

33

orange

channel 3 data bit 6

34

yellow

channel 3 data bit 5

35

green

channel 3 data bit 4

36

blue

channel 3 data bit 3

37

violet

channel 3 data bit 2

38

gray

channel 3 data bit 1

39

white

channel 3 data bit 0

40

black

+15 VDC unregulated power supply (fused for 1 amp)

Any eight digital devices or one eight bit analog device can be connected to any 1/4 J-6 cable as

shown. The LED between the ground (pin #1 brown) wire and supply (pin #10 black) wire acts as an indi-
cator which is lit if the fuse for that channel is OK:

G

ILDERFLUKE

& C

O

.¥ 205 S. F

LOWER

S

T

. ¥ B

URBANK

, CA 91502 ¥ 818/840-9484 ¥ 800/776-5972 ¥

FAX

818/840-9485

18 of 22

Advertising