PART 10 – INSTALLATION CHECKLIST


The following list is a guide only. Specific items will depend on the nature of the installation.

1 COLLECTOR FACES AS CLOSE AS POSSIBLE TO DUE NORTH/SOUTH.

Y N

2 COLLECTOR IS NOT SIGNIFICANTLY SHADED THROUGHOUT THE DAY.

Y N

3 COLLECTOR IS NOT LIKELY TO BE STRUCK BY FALLING OBJECTS SUCH AS BRANCHES OR FALLING FRUIT. Y N

4 COLLECTOR IS INSTALLED AT AN ANGLE OF BETWEEN 20

o

– 80

o

, PREFERABLY AT LATITUDE ANGLE.

Y N

5 IN AREAS PRONE TO LARGE HAIL (>3/4”), COLLECTOR IS INSTALLED AT AN ANGLE OF 40

o

OR GREATER. Y N

6 FRAME IS SECURED TO STRUCTURALLY SOUND ROOF/WALL.

Y N

7 PLUMBING IS LEAK FREE.

Y N

8 PLUMBING PIPE RUNS ARE WELL INSULATED.

Y N

9 INSULATION ABOVE ROOF LEVEL IS PROTECTED AGAINST SUNLIGHT WITH FOIL WRAP OR

EQUIVALENT.

Y N

10 CONTROLLER IS CONFIGURED CORRECTLY WITH FREEZE SETTING ON (IF REQUIRED).

Y N

11 SYSTEM IS FITTED WITH PRESSURE RELIEF VALVE ON THE COLLECTOR OUTLET AND/OR STORAGE

TANK.

Y N

12 PRESSURE RELIEF VALVE WILL DUMP ONLY ONTO HIGH TEMPERATURE RESISTANT MATERIAL AND

WILL NOT POSE A DANGER OF SCALDING PEOPLE.

Y N

13 PUMP, CONTROLLER, AND ALL ELECTRICAL CONNECTIONS ARE PROTECTED FROM WATER.

Y N

14 COLLECTORS HAVE BEEN CLEANED.

Y N

15 INSTALLATION RECORD FORM HAS BEEN GIVEN TO CUSTOMER AND BASIC OPERATION EXPLAINED.

Y N

16 FUNCTIONAL CHECKS FOR CONTROLLER AND PUMP HAVE BEEN COMPLETED.

Y N

17 WATER QUALITY HAS BEEN CHECKED (IF APPLICABLE).

Y N

18 COLLECTOR LOOP PIPING HAS BEEN FLUSHED AND CLEANED.

Y N










Advertising