4. Operational Conditions

38

4.3 Setting of Current Limiting Value at Pressing Operation

When having a pressing operation, set up the current limiting value which determines the pressing

force.

The graph below shows the current against the pressing force.

Take this as a reference for when making an adjustment to the pressing force.

There is no limit to the pressing duration. Continuous pressing can be performed.

Pressing Current Setting

30%

40%

50%

60%

70%

80%

Current Limiting Value [%]

10

9
8
7
6
5
4
3
2
1
0

Pressing force [N]

RA3L
RA2L
RA1L

* Under condition of horizontal orientation with no load or attached on the rod

Reference for Pressing Force

unit : [N]

Current Limiting Value

Type

30%

40%

50%

60%

70%

80%

RA1L

0.75

1

1.25

1.5

1.75

2

RA2L

1.5

2

2.5

3

3.5

4

RA3L

3

4

5

6

7

8

Caution: • The pressing force is adjusted with the current limiting value, and the fluctuation of

pressing force gets big when the current limiting value is low. It is recommended to

use the product in the range from 60% to 80% if possible.

• There may be a difference in the pressing force due to the variation of each unit or a

difference in the pressing position.

• Setting from 71% to 80% for the current limiting value may not be performed for

some versions of the PC software and teaching pendant.

Velocity at Pressing

20mm/sec