5. Maintenance Inspection

41

5. Maintenance Inspection

5.1 Inspection Items and Schedule

Follow the maintenance inspection schedule below.

It is assumed that the equipment is operating 8 hours per day.

If the equipment is running continuously night and day or otherwise running at a high operating rate,

inspect more often as needed.



External visual inspection

Start of operation

{



After 1 month of operation

{



After 3 months of operation

{



Every 3 months thereafter

{



After 3 years of operation, or upon reaching 5,000

km in traveled distance

{



Every year thereafter

{



5.2 External Visual Inspection

An external visual inspection should check the following things.

Main unit

Loose actuator mounting bolts, other loose items

Visual inspection on rod sliding area (should be no foreign

object to be put on)

Smooth movement of rod when moving it manually by hand

Cables

Scratches, proper connections

Overall

Irregular noise, vibration

5.3 Cleaning

Ɣ Clean exterior surfaces as necessary.

Ɣ Use a soft cloth to wipe away dirt and buildup.

Ɣ Do not blow too hard with compressed air as it may cause dust to get in through the gaps.

Ɣ Do not use oil–based solvents as they can harm lacquered and painted surfaces.

Ɣ To remove severe buildup, wipe gently with a soft cloth soaked in a neutral detergent or alcohol.