4 user wiring and piping – IAI America IX-NNC3515 User Manual

Page 30

Advertising
background image

24

5. Precautions for Use

5.4 User Wiring and Piping

The robot comes with standard cables and tubes that the user can use in a desired wiring/piping
configuration.

Panel Rear

panel

User connector specifications

Rated voltage

30 V

Permissible current

1.1 A

Conductor size and number of wires

AWG 26 (0.15 mm

2

), 15 wires

Other

Twisted-pair cable (1 to 14), shielded

Piping specifications

Normal service pressure

0.8 MPa

Dimensions (outer diameter x inner
diameter) and number of tubes

I4 mm x I2.5 mm, 3 pieces

Working medium

Air

ALM (indicator) specifications

Rated voltage

24 VDC

Rated current

12 mA

Illumination color

Red LED

Shape of Y-terminal

Spacer for user part installation

M4, depth 5

30 N or less

External force applied to the spacers must not
exceed 30 N in the axial direction or 2 N

˜m in

the rotating direction (for each spacer).

2 N

˜m or less

I 7

10

2.6 5.9

5.2

3.2

BK SW
Brake-release switch

Quick joint

I4 (red)

Quick joint

I4

(black)

Quick joint

I4 (white)

Spacer for user part installation

User connector

ALM (indicator)

Air tubes (

I4 x 3 pcs.)

U cable (outside robot)

PG cable (outside robot)

BK power cable (outside robot)

Suction pipe joint
(Applicable tube: Outer diameter

I12)

M cable (outside robot)