5. Precautions for Use

5.5 Suction

Rate

The robot will conform to cleanliness class 10 when air is sucked at a specified rate from the quick suction
joint provided on a side face of the base.
x The user must provide the suction device and suction air tube (I12).

Model

Suction rate (Nl/min)

IX-NNC50

……/60……

60

IX-NNC70

……/80……

80

Applicable tube:
Outer diameter

I12

(inner diameter

I8)

Quick suction joint

z The clean room must be designed as a down-flow environment.
z Cleanliness class 10 corresponds to a particle size of 0.1 Pm.
z The robot will generate dust if suction is not provided.