4 battery replacement, Caution warning – IAI America IX-NNC8040 User Manual

Page 50

Advertising
background image

44

6. Inspection/Maintenance

6.4 Battery

Replacement

6.4.1 Preparation

The following items are required when replacing the batteries:

x Phillips screwdriver
x New dedicated batteries for IX: AB-3 (4 pieces)

Before replacing the batteries, turn off the power to the controller, control panel and other relevant units.

z Performing inspection or maintenance without fully understanding the details of work may result in

a serious accident.

z Display a “Work in Progress” sign so that other operators will not operate the controller, operation

panel, etc.

z Use dedicated batteries for IX. Batteries for the old model (IH) cannot be used.
z Disassembly of the cover generates dust. Before disassembling the cover, move the robot to a

location where dust will not cause problem, or cover the robot with a plastic sheet, etc., to prevent
dust from scattering.

Caution

Warning

Advertising