9 ethercat® related parameters – IAI America PCON-CFA User Manual

Page 156

Advertising
background image

3. SCON-CA/CF

A

150

3.9

EtherCAT® Related Parameters

Parameters relating to EtherCAT® are No. 84 to No. 87 and No. 90.

Category: C :External interface parameter

No. Category Symbol

Name

Default Value set in

the Factory before

Delivery

1

~

83

Refer to Operation Manual for the
controller for the parameters No. 1
through No. 83.

84

C

FMOD

Field bus operation mode

0

85

C

NADR

Field bus node address

17

86

C

FBRS

Field bus baud rate

0

87 C NTYP

Network

type

6

90

C

FMIO

Field I/O format

3

159

C

FBVS

FB Half Direct Mode Speed Unit

0

z Field bus operation mode (No.84 FMOD)

Specify the operation mode in parameter No. 84 using a value between 0 and 4.

Value set in

parameter No. 84

Mode

Number of

occupied bytes

Contents

0 (Factory setting)

Remote I/O Mode

2

Operation using PIOs
(24 V I/Os) is performed via
EtherCAT(R).

1

Position/simple direct
mode

8

The target position can be set directly
using the value or the operation can be
performed using position data value.
The other values required for the
operation are set on the position data.

2

Half Direct Value Mode

16

In addition to the target position, the
speed, acceleration/deceleration and
pressing current value are set directly
using the values to perform the operation.

3

Full Direct Value Mode

32

All the values related to the position
control are set using the values to
perform the operation.

4

Remote I/O Mode 2

12

The current position and current speed
reading functions are added to the
functions in the remote I/O mode.

z Field bus node address (No.85 NADR)
Specify the node address number in parameter No. 85.

Setting Range 0 to 127 (It is set to “17” when the machine is delivered from the factory.)




Caution : Selecting a value between 17 and 80 (EtherCAT (R) I/O device range) is recommended

for node address if Omron’s master is being used.

If a value between 0 and 16 is selected, the Full Direct Value mode cannot be used.