138

Subnet mask (ML)

255

0~255

139

Subnet mask (L)

0

0~255

140

Default gateway (H)

0

0~255

141

Default gateway (MH)

0

0~255

142

Default gateway (ML)

0

0~255

143

Default gateway (L)

0

0~255

149

IAI protocol B/TCP: IP
address of connection
destination (MANU mode)
(H)

192

1~255

* Setting of “0” and “127” is prohibited.

150

IAI protocol B/TCP: IP
address of connection
destination (MANU mode)
(MH)

168 0~255

151

IAI protocol B/TCP: IP
address of connection
destination (MANU mode)
(ML)

0 0~255

152

IAI protocol B/TCP: IP
address of connection
destination (MANU mode)
(L)

100

1~254

* Setting of “0” and “255” is prohibited.

153

IAI protocol B/TCP: Port
number of connection
destination (MANU mode)

64611 0~65535

Mode setting in parameter No. 124:
* In the server mode “0” can be set.
0 = Ignore port number of connection destination

(Only the IP address is checked.)

* In the client mode “0” cannot be set.

154

IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(H)

192

1~255

* Setting of “0” and “127” is prohibited.

155

IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(MH)

168 0~255

156

IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(ML)

0 0~255

157

IAI protocol B/TCP: IP
address of connection
destination (AUTO mode)
(L)

100 1~254

* Setting of “0” and “255” is prohibited.

158

IAI protocol B/TCP: Port
number of connection
destination (AUTO mode)

64611 0~65535

Mode setting in parameter No. 124:
* In the server mode “0” can be set.
0 = Ignore port number of connection destination

(Only the IP address is checked.)

* In the client mode “0” cannot be set.

(Note) 1. To connect the controller to IAI’s PC software, set the parameter to “1: Client (Assign own port number

automatically.”

2. IAI’s PC software will detect “Error No. ECF: Socket error (PC)” if the controller-side port is disabled due to

a mode change on the controller side, reception of an IAI protocol serial-communication message or other
reason while the controller is connected to the PC software. This does not indicate abnormal status.

3. The connection will be cut off briefly during switching between the MANU and AUTO modes under IAI

protocol B/TCP, if the parameter settings of “own port number,” “client/server type,” “IP address of
connection destination” and “port number of connection destination” do not fully correspond between the
two modes.