12. Off Board T

uning Function on SCON-CA

Controller

177




12.5.3 Explanations for each Item in Carrier load Select Window

Set the carrier load in this window.

There are 2 ways for the selection of the carrier load, one is to indicate the carrier load and the other is to figure

out from the system identification, and selection can be made from these 2 ways.

(Note) The system identification is available to select only in the online work. In the offline work, the window

switches to the one as shown in Fig. 12.19.



Fig. 12.18 Carrier load Select Window (in online work)

[2] Carrier Load

Indication

[3] System Identification

Setting

[1] Carrier Load Indication

Method Select

[4] System Identification

Result