IAI America RCM-101-USB User Manual

Page 229

Advertising
background image

13. Frequency

Analysis Function for SCON-CA

Controller

Anti-V

ibration Control

217

13.2.2 Sampling Window

This window is used to import vibration data from the controller by moving the actuator.

You can also perform various operations in this window, such as setting the range of data used in FFT analysis

after vibration data has been imported from the controller or external measurement data or existing analysis

data (extension “fmd”) has been read.

When you select the “Import new controller data,” “Read external measurement data file” or “Read analytical

already data file (extension “fmd”)” option in the measurement data selection window, the display switches to

this window.

Fig. 13.10 Sampling Window

[1] Tool buttons [2] Sampling/FFT analysis result window switching

[5] Measurement data

[6] Data to be analyzed

[4] Sampling setting

[7] Execute FFT analysis

[3] FFT analysis setting

Advertising
This manual is related to the following products: