EARTH GROUND ROD INSTALLATION (OPTIONAL)

NOTE: For proper operation, do not connect the earth ground rod to the green
screw on the outlet plate.

Install earth ground rod within 3 feet (0.9 m) of the operator.

Disconnect and remove the green/yellow ground wire connected to the screw
terminal of the control board.

Attach earth ground rod wire to the screw terminal of the control board
marked

. Ensure the power wiring ground connection remains securely

connected to the green screw on the outlet plate.

FUSE
OPEN

Z1

FUSE
OPEN

R4

GATE 2

ACCESSORY

POWER

MAGLOCK

ALARM

GATE 1

J4

D15

C2

MOV2

C2

R4

24 VAC/

SOLAR

INPUT

J4

Ground Screw

Control Box

12 Gauge Wire

Earth Ground
Installation (Optional)

3' (0.9 m)

8' (2.4 m)

WIRING

» EARTH GROUND ROD INSTALLATION (OPTIONAL) + CONNECT BATTERIES

1

2

3

POWER

C64

BATT 1

BATT 2

C2

U2

BATT 1

MOV2

24 VAC/

INPUT

J4

USE DEDICATED CIRCUIT

CONNECT BATTERIES

The batteries are the main source of power for the operator. The operator is a
battery run system. Both batteries are charged in circuit using the transformer
(provided). The 24 Vac input can accept a charging transformer (26 Vac, 29 VA or
36 Vdc, 40 VA).

Connect the plugs from the batteries to the connectors on the control board.