Loop inputs, Photo/edge inputs (p6-7-8 and 9), Additional – LiftMaster LA400 Residential DC Linear Gate Operator User Manual

Page 38: Features, Loop inputs + photo/edge inputs (p6-7-8 and 9)

Advertising
background image

FREQ

PRESENCE

RELA

Y 2

SEN

S

FREQ

MADE IN USA

C2

S8

LOOP

INPUTS

SHADOW

INTERRUPT

GR

LD

COM

LOOP

INPUTS

BATT 1

BATT 2

A 32V

SHADOW LOOP INPUT TERMINAL AND COMMON
This input protects cars by preventing the gate from moving off of the open or close
limit when the shadow loop input is active.
NOTE: Shadow loop is disabled when gate is moving.

INTERRUPT LOOP INPUT TERMINAL AND COMMON
This input functions to reverse a closing gate to the open limit. Latching this input
will reset the timer to close.

NOTE: Additional enclosure required.
Refer to loop detector manufacturer
instructions for connections.

NORMALLY OPEN SHADOW LOOP

NORMALLY OPEN INTERRUPT LOOP

COMMON LOOP

ADDITIONAL

FEATURES

» LOOP INPUTS + PHOTO/EDGE INPUTS (P6-7-8 AND 9)

37

EXIT LOOP

LOOP INPUTS

OPEN INPUT AND EXIT LOOP
These terminals are intended for use as a general open control. Accessories such as
telephone entry systems, radio receivers (open only applications), exit loop
detectors, keypads and 7-day timers may be wired to this input.

PHOTO/EDGE INPUTS (P6-7-8 AND 9)

TERMINAL P6 – CLOSE SAFETY EDGE
This input will reverse a closing gate. It will disable the Timer-to-Close if that feature
has been enabled. Activating this input while the gate is opening will have no effect.
Order part number LA400-BOX to enclose safety electronics.

TERMINAL P8 – OPEN SAFETY EDGE/PHOTOELECTRIC SENSOR (ENTRAPMENT)
If an Open Edge device or a Retro-Reflective Photoelectric Sensor has been
connected to Terminal P8, then this input will reverse an opening gate for 2 seconds
then stop. Activating this input with an Open Edge device or a Retro-Reflective
Photoelectric Sensor connected to Terminal P8 while the gate is closing will have no
effect.
If a Chamberlain Pulsing Photoelectric Sensor (See Accessories) has been connected
to Terminal P8, then this input will pause an opening gate until the obstruction
has been removed. Upon removing the obstruction, the gate will continue to open.
Activating this input with a Chamberlain Pulsing Photoelectric Sensor
(See Accessories) connected to Terminal P8 while the gate is closing will have
no effect.

TERMINAL P7 – OPEN SAFETY PHOTOELECTRIC SENSOR (ENTRAPMENT)
This input will pause an opening gate until the obstruction has been removed. Upon
removing the obstruction, the gate will continue to open. Activating this input while
the gate is closing will have no effect.

TERMINAL P9 – CLOSE SAFETY PHOTOELECTRIC SENSOR
This input will reverse a closing gate to the open limit. Activating this input while the
gate is opening will have no effect. The Timer-to-Close will reactivate at the open
limit.

CLOSE
EDGE

OPEN EDGE

PHOTO

OPEN

PHOTO

CLOSE
PHOTO

C2

CLOSE
EDGE

OPEN EDGE/

PHOTO

OPEN
PHOTO

CLOSE
PHOTO

blue

blue

blue

blue

blue

brown

brown

blue

brown

brown

brown

brown

Advertising