Control inputs, Additional, Features – LiftMaster LA400 Residential DC Linear Gate Operator User Manual

Page 37: And/or, And/or 36

Advertising
background image

CONTROL

INPUTS

OPEN

SINGLE BUTTON

RESET

STOP

COM

COM

COM

COM

M

M

M

M

M

M

CONTROL

INPUTS

OPEN

SINGLE BUT T O N

RESET

S T O P

POWER

CONTROL INPUTS

WIRE STOP BUTTON (OPTIONAL)
A jumper wire is factory installed between the stop and common input.
Stop (N/C) - Stop only (does not reset alarm).
NOTE: Stop jumper is required for normal operation (the Stop LED will be lit
except when the control board goes into Sleep Mode). Remove only if remotely
mounted Stop button is added.

OPEN
Opens only or reverses a closing gate.

SBC (SINGLE BUTTON CONTROL) INPUT
This input will command the gate to OPEN / STOP / CLOSE / STOP in sequence.

RESET CONTROL INPUT
The control box has a factory installed internal reset button. These terminals are
intended for use with a single reset button that is installed within line of sight of the
gate. This input functions to reset the alarms. This input will NOT stop the gate.
NOTE: All Control Inputs must be Normally Open (N.O.) dry contact type.

OPEN

COMMON

SINGLE BUTTON

COMMON

COMMON

RESET

AND/OR

AND/OR

36

ADDITIONAL

FEATURES

» CONTROL INPUTS

C2

CONTROL

INPUTS

OPEN

SINGLE BUTTON

RESET

STOP

COM

COM

COM

COM

M

M

M

M

M

M

CONTROL

INPUTS

OPEN

SINGLE BUT T O N

RESET

S T O P

POWER