Chapter Four
Control Reference
This control allows you to control the precision or resolution in the percentage. The default is 1%. But
you can set the resolution to as low as 1e-6 % (one part in 1e8). This is useful for finding approximate
confidence limits.
PctRes
From 1e-006 to 1 step 0.01, locked to 1 2 5, fine grain allowed=false, on=false
DoubleLockstep
Range
Description
PERSISTDCD
app.Measure.Px.Operator (ParamEngine = "PersistDCD")
High level in percent.
LowPct
From 10 to 40 step 1
Double
Range
Description
High level in percent.
HighPct
From 60 to 90 step 1
Double
Range
Description
For eye-diagram parameters which have an "aperture" setting, this defines the region over which the
eye digrams vertical information is analyzed.
It specifies the percentage of the central region of the eye (relative to 1 Unit Interval) which is used in
the analysis.
Aperture
From 0 to 100 step 0.1
Double
Range
Description
Aperture
Double
HighPct
Double
LowPct
Double
916435 RevA
4-36